    "$id": "PullDynamicScheduleUpdateResponse",
    "comment": "OCPP 2.1 Edition 1 (c) OCA, Creative Commons Attribution-NoDerivatives 4.0 International Public License",
    "definitions": {
        "ChargingProfileStatusEnumType": {
            "description": "Result of request.\r\n\r\n",
            "javaType": "ChargingProfileStatusEnum",
            "type": "string",
            "additionalProperties": false,
            "enum": ["Accepted", "Rejected"],
            "tsEnumNames": ["Accepted", "Rejected"]
        },
        "ChargingScheduleUpdateType": {
            "description": "Updates to a ChargingSchedulePeriodType for dynamic charging profiles.\r\n\r\n",
            "javaType": "ChargingScheduleUpdate",
            "type": "object",
            "additionalProperties": false,
            "properties": {
                "limit": {
                    "description": "Optional only when not required by the _operationMode_, as in CentralSetpoint, ExternalSetpoint, ExternalLimits, LocalFrequency,  LocalLoadBalancing. +\r\nCharging rate limit during the schedule period, in the applicable _chargingRateUnit_. \r\nThis SHOULD be a non-negative value; a negative value is only supported for backwards compatibility with older systems that use a negative value to specify a discharging limit.\r\nFor AC this field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\n",
                    "type": "number"
                },
                "limit_L2": {
                    "description": "*(2.1)* Charging rate limit on phase L2  in the applicable _chargingRateUnit_. \r\n",
                    "type": "number"
                },
                "limit_L3": {
                    "description": "*(2.1)* Charging rate limit on phase L3  in the applicable _chargingRateUnit_. \r\n",
                    "type": "number"
                },
                "dischargeLimit": {
                    "description": "*(2.1)* Limit in _chargingRateUnit_ that the EV is allowed to discharge with. Note, these are negative values in order to be consistent with _setpoint_, which can be positive and negative.  +\r\nFor AC this field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\n",
                    "type": "number",
                    "maximum": 0
                },
                "dischargeLimit_L2": {
                    "description": "*(2.1)* Limit in _chargingRateUnit_ on phase L2 that the EV is allowed to discharge with. \r\n",
                    "type": "number",
                    "maximum": 0
                },
                "dischargeLimit_L3": {
                    "description": "*(2.1)* Limit in _chargingRateUnit_ on phase L3 that the EV is allowed to discharge with. \r\n",
                    "type": "number",
                    "maximum": 0
                },
                "setpoint": {
                    "description": "*(2.1)* Setpoint in _chargingRateUnit_ that the EV should follow as close as possible. Use negative values for discharging. +\r\nWhen a limit and/or _dischargeLimit_ are given the overshoot when following _setpoint_ must remain within these values.\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\n",
                    "type": "number"
                },
                "setpoint_L2": {
                    "description": "*(2.1)* Setpoint in _chargingRateUnit_ that the EV should follow on phase L2 as close as possible.\r\n",
                    "type": "number"
                },
                "setpoint_L3": {
                    "description": "*(2.1)* Setpoint in _chargingRateUnit_ that the EV should follow on phase L3 as close as possible. \r\n",
                    "type": "number"
                },
                "setpointReactive": {
                    "description": "*(2.1)* Setpoint for reactive power (or current) in _chargingRateUnit_ that the EV should follow as closely as possible. Positive values for inductive, negative for capacitive reactive power or current.  +\r\nThis field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.\r\n",
                    "type": "number"
                },
                "setpointReactive_L2": {
                    "description": "*(2.1)* Setpoint for reactive power (or current) in _chargingRateUnit_ that the EV should follow on phase L2 as closely as possible. \r\n",
                    "type": "number"
                },
                "setpointReactive_L3": {
                    "description": "*(2.1)* Setpoint for reactive power (or current) in _chargingRateUnit_ that the EV should follow on phase L3 as closely as possible. \r\n",
                    "type": "number"
                },
                "customData": {
                    "$ref": "#/definitions/CustomDataType"
                }
            }
        },
        "StatusInfoType": {
            "description": "Element providing more information about the status.\r\n",
            "javaType": "StatusInfo",
            "type": "object",
            "additionalProperties": false,
            "properties": {
                "reasonCode": {
                    "description": "A predefined code for the reason why the status is returned in this response. The string is case-insensitive.\r\n",
                    "type": "string",
                    "maxLength": 20
                },
                "additionalInfo": {
                    "description": "Additional text to provide detailed information.\r\n",
                    "type": "string",
                    "maxLength": 1024
                },
                "customData": {
                    "$ref": "#/definitions/CustomDataType"
                }
            },
            "required": ["reasonCode"]
        },
        "CustomDataType": {
            "description": "This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.",
            "javaType": "CustomData",
            "type": "object",
            "properties": {
                "vendorId": {
                    "type": "string",
                    "maxLength": 255
                }
            },
            "required": ["vendorId"]
        }
    },
    "type": "object",
    "additionalProperties": false,
    "properties": {
        "scheduleUpdate": {
            "$ref": "#/definitions/ChargingScheduleUpdateType"
        },
        "status": {
            "$ref": "#/definitions/ChargingProfileStatusEnumType"
        },
        "statusInfo": {
            "$ref": "#/definitions/StatusInfoType"
        },
        "customData": {
            "$ref": "#/definitions/CustomDataType"
        }
    },
    "required": ["status"]
}