 * Represents the available commands for various devices such as the Motherboard and Tindeq Progressor.
 */
export interface Commands {
    /**
     * Starts a weight measurement on the device.
     * Used to begin collecting weight or force data.
     */
    START_WEIGHT_MEAS?: string | Uint8Array;
    /**
     * Stops the current weight measurement on the device.
     * Used to end the data collection.
     */
    STOP_WEIGHT_MEAS?: string | Uint8Array;
    /**
     * Puts the device to sleep or in a low-power mode.
     * The format can be a string or a number depending on the device.
     */
    SLEEP?: number | string | Uint8Array;
    /**
     * Retrieves the serial number of the device.
     * This command fetches the unique identifier assigned by the manufacturer.
     */
    GET_SERIAL?: string | Uint8Array;
    /**
     * Retrieves textual information from the device.
     * May include readable data.
     */
    GET_TEXT?: string | Uint8Array;
    /**
     * Starts or stops a debug data stream from the device.
     * Used for diagnostic purposes or to monitor real-time data.
     */
    DEBUG_STREAM?: string | Uint8Array;
    /**
     * Retrieves calibration data from the device.
     * Used to ensure accurate measurements by applying calibration points.
     */
    GET_CALIBRATION?: string | Uint8Array;
    /**
     * Sets the Force Board into Quick Start mode.
     * In this mode, data transmission starts when force exceeds the threshold
     * and stops when force drops below the threshold.
     */
    START_QUICK_MEAS?: string | Uint8Array;
    /**
     * Tares the scale, zeroing the current weight measurement.
     * Used to reset the baseline for weight data.
     */
    TARE_SCALE?: string | Uint8Array;
    /**
     * Starts measuring the peak rate of force development (RFD).
     * Captures how quickly force is applied over time.
     */
    START_PEAK_RFD_MEAS?: string | Uint8Array;
    /**
     * Starts measuring a series of peak RFD measurements.
     * This captures multiple RFD data points over a period of time.
     */
    START_PEAK_RFD_MEAS_SERIES?: string | Uint8Array;
    /**
     * Adds a calibration point to the device.
     * Used to improve the accuracy of future measurements.
     */
    ADD_CALIBRATION_POINT?: string | Uint8Array;
    /**
     * Saves the current calibration settings to the device.
     * Ensures the device remembers the calibration for future sessions.
     */
    SAVE_CALIBRATION?: string | Uint8Array;
    /**
     * Retrieves the firmware version of the device.
     * Useful for ensuring compatibility and tracking updates.
     */
    GET_FIRMWARE_VERSION?: string | Uint8Array;
    /**
     * Retrieves error information from the device.
     * Provides details on any faults or issues that occurred during operation.
     */
    GET_ERROR_INFORMATION?: string | Uint8Array;
    /**
     * Clears the error information on the device.
     * Used to reset error logs after troubleshooting or repair.
     */
    CLR_ERROR_INFORMATION?: string | Uint8Array;
    /**
     * Retrieves the battery voltage level of the device.
     * Provides insight into the device's remaining battery power.
     */
    GET_BATTERY_VOLTAGE?: string | Uint8Array;
    /**
     * Retrieves a temperature reading from the device.
     */
    GET_TEMPERATURE?: string | Uint8Array;
    /**
     * Retrieves the current weight from the device.
     */
    GET_WEIGHT?: string | Uint8Array;
    /**
     * Sets the device capacity/range.
     * Payload selects the target range.
     */
    SET_RANGE?: string | number | Uint8Array;
    /**
     * Sets the display division value.
     * Payload selects the target division.
     */
    SET_DIVISION?: string | number | Uint8Array;
    /**
     * Sets the first calibration reference weight.
     * Payload selects the target calibration mass.
     */
    SET_FIRST_CALIBRATION_WEIGHT?: string | number | Uint8Array;
    /**
     * Sets the second calibration reference weight.
     * Payload selects the target calibration mass.
     */
    SET_SECOND_CALIBRATION_WEIGHT?: string | number | Uint8Array;
    /**
     * Runs the no-load calibration routine.
     */
    NO_LOAD_CALIBRATION?: string | Uint8Array;
    /**
     * Runs the first calibration step after the reference mass is applied.
     */
    RUN_FIRST_CALIBRATION?: string | Uint8Array;
    /**
     * Runs the second calibration step after the reference mass is applied.
     */
    RUN_SECOND_CALIBRATION?: string | Uint8Array;
    /**
     * Configures the automatic shutdown timer.
     * Payload selects the timeout or disables it.
     */
    SET_SHUTDOWN_TIME?: string | number | Uint8Array;
    /**
     * Configures the upper temperature limit threshold.
     */
    SET_UPPER_TEMPERATURE_LIMIT?: string | number | Uint8Array;
    /**
     * Configures the lower temperature limit threshold.
     */
    SET_LOWER_TEMPERATURE_LIMIT?: string | number | Uint8Array;
    /**
     * Configures the upper/max weight limit threshold.
     */
    SET_MAX_WEIGHT_LIMIT?: string | number | Uint8Array;
    /**
     * Configures the lower/min weight limit threshold.
     */
    SET_MIN_WEIGHT_LIMIT?: string | number | Uint8Array;
    /**
     * Configures the weight-alarm behavior for the configured upper/lower thresholds.
     */
    SET_WEIGHT_ALARM_MODE?: string | number | Uint8Array;
    /**
     * Enables or disables alarm-frame output over the serial/BLE transport.
     */
    SET_ALARM_OUTPUT?: string | number | Uint8Array;
    /**
     * Get the Progressor ID.
     */
    GET_PROGRESSOR_ID?: string | Uint8Array;
    /**
     * Set calibration block. Payload at offsets +2,+6,+10.
     * The 12-byte block is interpreted as 3× float32 LE: slope, intercept, trim.
     */
    SET_CALIBRATION?: string | Uint8Array;
    /**
     * Retrieves the advanced calibration table from the device.
     * Used to inspect the hidden piecewise interpolation table exported by v2 firmware.
     */
    GET_CALIBRATION_TABLE?: string | Uint8Array;
    /**
     * Controls whether the device resets to zero on power-up.
     */
    POWER_ON_RESET?: string | number | Uint8Array;
    /**
     * Updates the device's hardware zero point.
     */
    ZERO_SCALE?: string | number | Uint8Array;
    /**
     * Toggles the device's peak mode.
     */
    PEAK_MODE?: string | number | Uint8Array;
    /**
     * Configures the device UART baud rate.
     */
    SET_BAUD_RATE?: string | number | Uint8Array;
    /**
     * Configures the device sampling rate.
     */
    SET_SAMPLING_RATE?: string | number | Uint8Array;
    /**
     * Reboots the device immediately.
     * Intended for diagnostic flows.
     */
    REBOOT?: string | Uint8Array;
}
//# sourceMappingURL=command.interface.d.ts.map