{
    "label": {
        "host": "Host",
        "showEWIO2": "Show all discovered EWIO2",
        "searchEWIO2": "Search EWIO2",
        "encryption": "Enable secure (SSL/TLS) connection",
        "tlsConfig": "TLS configuration",
        "user": "User",
        "password": "Password",
        "name": "Name",

        "port": "Port",
        "valueConfig": "Config.",
        "status": "State",
        "value": "Value",
        "manualMode": "Man. mode",
        "pulseCntr": "Pulse count.",
        "trigger": "Node reacts to...",
        "inputSignal": "Input signal at node",
        "risingEdge": "Rising edge at EWIO2",
        "fallingEdge": "Falling edge at EWIO2",
        "valueUpdate": "Change in value at EWIO2",
        "counter": "Meter",
        "datapoint": "Datapoint",
        "timestamp": "Timestamp",
        "range": "Range",
        "nodeOutput": "Additional node output values...",
        "loadMeasurements": "Load measured values from the data base...",
        "quantity": "Quantity"
    },
    "status": {
        "nodeRedNotAvailable": "Node-RED not available!",
        "nodeRedNotRunning": "Node-RED not running!",
        "notAuthorized": "Wrong credentials!",
        "configNodeMissing": "Incorrect EWIO2 configuration!",
        "notReachable": "Cannot connect to EWIO2! __error__",
        "noConnection": "No connection to EWIO2",
        "portCommError": "Communication problem with port!",
        "timeout": "Timeout, EWIO2 not reachable! __error__",
        "timeoutWsMsg": "Communication problem with EWIO2!",
        "invalidURL": "Invalid hostname",
        "missingCertificate": "Certificate missing!",
        "selfSignedCertificate": "Self signed certificate!",
        "invalidCertificateAltname": "Hostname does not match certificate's altnames! __error__",
        "tlsConfigMissing": "No TLS configuration available!",
        "unhandeledError": "Error! __error__",
        "connected": "Connected",

        "missingEwio": "EWIO2 missing!",
        "missingHost": "Hostname missing!",
        "missingUser": "Username missing!",
        "missingPw": "Password missing!",
        "missingEnc": "Encryption flag missing!",
        "manualModeActive": "Manual mode active!",
        "counterDeactivated": "Meter deactivated!",
        "noBoolOrNumber": "No input signal of type 'boolean' or 'number'!",
        "noNumber": "No input signal of type 'number'!",
        "noObject": "Payload of input signal is not type 'object'!",
        "noFromTo": "Payload of input signal is missing a 'from' and/or 'to' element!",
        "wrongMsgTopicType": "No input signal of type 'string'!",
        "wrongMsgTopic": "Unknown input topic!",
        "notPulseCntr": "Port is not a pulse counter!",
        "triggerInputInactive": "Trigger on input signal deactivated",
        "insufficientAccessRights": "No Permission for user: Standard!",
        "bacnetServerActive": "Output is controlled via BACnet!",
        "missingPort": "'Port' missing!",
        "aiConfigWarning": "DIP-switch 1 must be set to ON for current measurement!",
        "aiConfigInfo": "The configuration will be set immediately at EWIO2 on change!",
        "no_metering": "EWIO2 without metering interface!",
        "noCounter": "No meter configured at EWIO2!",
        "noData": "No data available yet!",
        "getMeasurementsFailed": "Retrieving data failed!",
        "loginFailed": "Login failed to retrieve data"
    },
    "ewio2Info": {
        "noEWIO2": "No EWIO2 discovered!",
        "noInfo": "No information available!",
        "host": "Host",
        "ipAddress": "IP address",
        "thisDevice": "this EWIO2",
        "macAddress": "MAC address",
        "hwModel": "Model",
        "serial": "Serial number",
        "swVersion": "Version",
        "location": "Location"
    },
    "settings": {
        "logEnabled": "Logging",
        "logfilePath": "Path"
    },
    "sensorAI": {
        "inactive_": "Input inactive",
        "volt_0_10_pc_%": "Voltage measurement: 0 - 10 V (0..100%)",
        "volt_0_5_pl_pc_%": "Voltage measurement: 0 - 5 V Pullup (0..100%)",
        "volt_0_10_V": "Voltage measurement: 0 - 10 V",
        "volt_0_5_pl_V": "Voltage measurement: 0 - 5 V Pullup",
        "ohm_40_4m_ohm": "Resistance measurement: 40 Ohm - 4 MOhm",
        "usr_def": "User defined",
        "pt100_°C": "Sensor type: PT100 (-50..+150 °C)",
        "pt500_°C": "Sensor type: PT500 (-50..+150 °C)",
        "pt1000_°C": "Sensor type: PT1000 (-50..+150 °C)",
        "ni1000_tc5000_°C": "Sensor type: Ni1000-Tc5000 (-50..+150 °C)",
        "ni1000_tc6180_°C": "Sensor type: Ni1000-Tc6180 (-50..+150 °C)",
        "balco500_°C": "Sensor type: Balco500 (-40..+150 °C)",
        "kty81_110_°C": "Sensor type: KTY81_110 (-40..+150 °C)",
        "kty81_210_°C": "Sensor type: KTY81_210 (-40..+150 °C)",
        "ntc_1k8_th_°C": "Sensor type: NTC1K8 Thermokon (-50..+150 °C)",
        "ntc_5k_th_°C": "Sensor type: NTC5K Thermokon (-50..+150 °C)",
        "ntc_10k_th_°C": "Sensor type: NTC10K Thermokon (-50..+150 °C)",
        "ntc_20k_th_°C": "Sensor type: NTC20K Thermokon (-50..+150 °C)",
        "lm235z_°C": "IC temperature sensor: LM235Z (-50..150 °C)",
        "ntc_10k_carel_°C": "Sensor type: NTC10K Carel (-50..+110 °C)",
        "ntc_5k_sch_°C": "Sensor type: NTC5K Schneider (-50..+150 °C)",
        "ntc_30k_sch_°C": "Sensor type: NTC30K Schneider (-50..+150 °C)",
        "kp250_°C": "Sensor type: KP250 (-50..+150°C)",
        "poti_10k_pc_%": "Sensor type: Potentiometer 10 kOhm (0..100%)",
        "inactive2_": "Input inactive",
        "ampere_0_20_pc_%": "Current measurement: 0 - 20 mA (0..100%)",
        "ampere_0_20_mA": "Current measurement: 0 - 20 mA",
        "ampere_4_20_pc_%": "Current measurement: 4 - 20 mA (0..100%)",
        "ampere_4_20_mA": "Current measurement: 4 - 20 mA",
        "3wire_sens_0_14k_kohm": "3 Wire sensing: 0 - 14 kOhm",
        "4wire_sens_0_14k_kohm": "4 Wire sensing: 0 - 14 kOhm"
    },
    "dpRanges": {
        "interval_30s": "30 seconds",
        "interval_20s": "20 seconds",
        "interval_15s": "15 seconds",
        "interval_10s": "10 seconds",
        "interval_5s": "5 seconds",
        "interval_1s": "1 second",
        "interval_syncpulse": "Synchronous-pulse",
        "interval_event": "Event-based",
        "interval_none": "-",
        "interval_1min": "1 minute",
        "interval_5min": "5 minutes",
        "interval_10min": "10 minutes",
        "interval_15min": "15 minutes",
        "interval_30min": "30 minutes",
        "interval_1h": "1 hour",
        "interval_2h": "2 hours",
        "interval_4h": "4 hours",
        "interval_6h": "6 hours",
        "interval_12h": "12 hours",
        "interval_daily": "Daily",
        "interval_weekly": "Weekly",
        "interval_monthly": "Monthly",
        "interval_quarterly": "Quarter yearly",
        "interval_semiannual": "Half yearly",
        "interval_yearly": "Yearly"
    }
}

