## Description 
These are nodes for Grunig.

All the nodes require an additional node for the functions (mqtt-node, opcua-client, influxdb out, modbus-read). 

Every node (except for the OpcUa-Read) also requires an function node with the code in the node-description to get the right format for node-input. 

There is an example flow for the relevant nodes. 

Node-Red:
- [Node-Red: grunig-nodes](https://flows.nodered.org/node/grunig-nodes)
- [Node-Red: flow example](https://flows.nodered.org/flow/c758a918fd0cb3f8f7f7ace8c09cec95)





## relevant Nodes

<details><summary>Modbus-Read

*Reads data from Modbus and puts it in MQTT*
</summary>

> ## Transfer of Values
> The values Payload, Communication, and MachineID must be passed through a Function Node.
> 
> Code:
> ```js
>     let value = msg.payload;
>     msg.payload = {};
>     msg.payload.Value = value;
>     msg.payload.MachineID = flow.get("fMachineID");
>     msg.payload.Communication = flow.get("fCommunication");
>     return msg;
> ```
> 
> 
> ## MQTT Path
> Here must be the MQTT path where the data should be written.
> 
> Example:  
> 
>     Error
> 
> 
> 
> ## Format
> The desired format can be selected.
> 
> ## payload
> Only the payload value is output.
> 
> Example: 
> 
>     Main_Warning = 0
> 
> ## unit
> The payload value and a unit are output.
> 
> Example: 
> 
>     ProgramNumber = {"value":0,"unit":"#"}
> 
> 
> 
> ## Communication
> It can be selected whether the values are set to 0 if there is no active connection to the machine.
> 
> Value should be retained if connection is lost:
> 
>     ignore
> 
> Value should be set to 0 if connection is lost:
> 
>     consider
> 
> 
> 
> ## Data x
> Here come the variable names after the Topic-Path.
> 
> The square brackets must specify the array in which the value is stored.
> 
> This usually corresponds to the last two digits of the Modbus address.
> 
> Digit example: 
> 
>     Modbus address: 32110  --> last two digits = [10]
> 
> Input: 
> 
>     Main_Warning [10]
> 
> ## Format = unit
> If the format is **unit**, then the unit must be specified in another square bracket.
> 
> Example:
> 
>     ProgramNumber [30] [#]
>     
> 
> 
> ## Example Path
> The path is constructed as follows:
> 
>     "GRUNIG/MachineID/" + MQTT Path + Data x
> 
> In the example, we have *Error* as the MQTT Path and *Main_Warning* as Data x.
> 
> This means, in the example, the value will be written to this path in the MQTT broker:
> 
>     GRUNIG/MachineID/Error/Main_Warning


</details>

<details><summary>OpcUa-Read

*Reads OpcUa data and puts it in MQTT*
</summary>

> ## Path
> Here must be the path of the OpcUa variables (with "**.**" at the end).
> 
> Example:
> 
>     ns=6;s =:: Industry40:Interface.State.
> 
> 
> 
> ## Value
> Here a specific value can be entered to be written to the variables.
> 
> If the value should be taken from the payload, leave it empty.
> 
> 
> 
> ## Data x
> Here come the names of the variables that come after the path in the OpcUa server.
> 
> The data type of each variable must be written in square brackets "**[ ]**" after the variable name.
> 
> Example:
> 
>     bCommunication [Boolean]
> 
> ### Permissible Variables
> | Type                | Description              |
> |---------------------|--------------------------|
> | Int8                | 8-Bit Integer            |
> | Int16               | 16-Bit Integer           |
> | Int32               | 32-Bit Integer           |
> | Int64               | 64-Bit Integer           |
> | UInt8               | 8-Bit Unsigned Integer   |
> | UInt16              | 16-Bit Unsigned Integer  |
> | UInt32              | 32-Bit Unsigned Integer  |
> | UInt64              | 64-Bit Unsigned Integer  |
> | Byte                | Byte                     |
> | SByte               | Signed Byte              |
> | Float               | Floating Point Number    |
> | Double              | Double                   |
> | Boolean             | Boolean                  |
> | String              | String                   |
> | LocalizedText       | Localized Text           |
> | DateTime            | Date and Time            |
> | Int8 Array          | Array of Int8            |
> | Int16 Array         | Array of Int16           |
> | Int32 Array         | Array of Int32           |
> | UInt8 Array         | Array of UInt8           |
> | UInt16 Array        | Array of UInt16          |
> | UInt32 Array        | Array of UInt32          |
> | Byte Array          | Array of Byte            |
> | SByte Array         | Array of Signed Byte     |
> | String Array        | Array of Strings         |
> | Float Array         | Array of Floats          |
> | Double Array        | Array of Doubles         |
> | Boolean Array       | Array of Booleans        |
> | ExtensionObject     | Extension Object         |
> | ExtensionObject Array | Array of Extension Objects |


</details>



<details><summary>MQTT-InfluxDB-Write

*Writes MQTT to InfluxDB or OpcUa to MQTT*
</summary>

>## Transfer of Values
>The values `Payload` and `MachineID` must be passed through a Function Node.
>
>Code: 
>
>```js
>let value = msg.payload;
>msg.payload = {};
>msg.payload.MachineID = flow.get("fMachineID");
>msg.payload.Value = value;
>return msg;
>```
>
>
>
>## Path Construction
>The path is constructed as follows:
>
>    "GRUNIG/MachineID/" + Topic-Path + Data x
>In the example, we have */State* as the Topic-Path and *MachineState* as Data x.
>
>This means, in the example, the value will be written to this path in the MQTT broker:
>
>    ```GRUNIG/MachineID/State/MachineState```
>
>
>
>
>### Topic-Path
>Here comes the path from MQTT, even if >**write InfluxDB** is selected.
>
>Example: 
>
>    /State
>
>
>
>
>## Action
>You can choose whether to write to MQTT or to InfluxDB.
>
>
>
>
>## Format
>If **write MQTT** is selected in Action, then the format can be chosen here.
>
>
>
>
>### Format Example: **Alarm message**
>    
>    "value": "1",
>    "description": "ALARM_STATE_ACTIVE"
>
>### Format Example: **Unit**
>
>    "value": "5",
>    "unit": "s",
>
>
>
>## Type
>If **write InfluxDB** is selected in Action, then the type can be determined here.
>
>Example: **State**
>
>    MachineState: 1
>    "_type": State
>
>
>
>## Data x
>Here come the variable names after the Topic-Path.
>
>Example: 
>
>   ```MachineState```

</details>


<details><summary>AlarmOutput

*Reads the MQTT from the input JSON and puts it in InfluxDB format. Reads the Alarm-Input Bitwise.*
</summary>

>## Alarm List
>This is where alarm messages are specified.
>```js
>   "Enable": true,
>    "Alarm": "Main A00",
>    "Message": [
>        "Error 0",
>        "Fehler 0"
>    ]
>```
>## Enable
> The **Enable** parameter is used to disable individual alarms.
>
>    true: Alarm is triggered
>
>    false: Alarm is not triggered
> 
>## Alarm
> Name of the alarm.
>
>```json 
>"Main A00" 
>```
>
>## Message
> The first string contains the error message in English.
>
>```json 
>"Error 0" 
>```
>
> The second string contains the error message in German.
>  
>```json 
>"Fehler 0" 
>```
>
> 
>
>## Path MQTT
> This specifies the path from the MQTT broker for the alarms.
>
>```cd
>Error/Main_Warning
>```
>
</details>