import { PropertyDataType } from './deviceProperties';
export declare enum NodeTypes {
    VENTILATION_UNIT = 1,
    OPTION_BOX = 2,
    COMFOCONTROL_GATEWAY = 55
}
export declare enum ErrorCodes {
    NO_ERROR = 0,
    UNKNOWN_COMMAND = 11,
    UNKNOWN_UNIT = 12,
    UNKNOWN_SUBUNIT = 13,
    UNKNOWN_PROPERTY = 14,
    TYPE_CANNOT_HAVE_RANGE = 15,
    VALUE_NOT_IN_RANGE = 30,
    PROPERTY_NOT_GETTABLE_OR_SETTABLE = 32,
    INTERNAL_ERROR = 40,
    INTERNAL_ERROR_COMMAND_WRONG = 41
}
export interface NodeProperty {
    node: NodeTypes;
    unit: UnitTypes;
    /**
     * Defaults to 1 when not specified.
     */
    subunit?: number;
    propertyId: number;
    dataType: PropertyDataType;
    access?: 'ro' | 'rw';
}
/**
 * Enum representing different node types.
 */
export declare enum UnitTypes {
    /** NODE: Represents the general node with attributes like serial nr, etc. (1 SubUnit) */
    NODE = 1,
    /** COMFOBUS: Unit responsible for comfobus-communication. Probably stores the ID's of connected devices. (1 SubUnit) */
    COMFOBUS = 2,
    /** ERROR: Stores errors, allows errors to be reset (1 SubUnit) */
    ERROR = 3,
    /** SCHEDULE: Responsible for managing Timers, the schedule, etc. Check here for level, bypass etc. (10 SubUnits) */
    SCHEDULE = 21,
    /** VALVE: ??? Bypass PreHeater and Extract (2 SubUnits) */
    VALVE = 22,
    /** FAN: Represents the two fans (supply, exhaust) (2 SubUnits) */
    FAN = 23,
    /** POWERSENSOR: Counts the actual wattage of ventilation and accumulates to year and since factory reset (1 SubUnit) */
    POWERSENSOR = 24,
    /** PREHEATER: Represents the optional preheater (1 SubUnit) */
    PREHEATER = 25,
    /** HMI: Represents the Display + Buttons (1 SubUnit) */
    HMI = 26,
    /** RFCOMMUNICATION: Wireless-communication with attached devices (1 SubUnit) */
    RFCOMMUNICATION = 27,
    /** FILTER: Counts the days since last filter change (1 SubUnit) */
    FILTER = 28,
    /** TEMPHUMCONTROL: Controls the target temperature, if its cooling or heating period and some settings (1 SubUnit) */
    TEMPHUMCONTROL = 29,
    /** VENTILATIONCONFIG: Responsible for managing various configuration options of the ventilation (1 SubUnit) */
    VENTILATIONCONFIG = 30,
    /** NODECONFIGURATION: Manages also some options (1 SubUnit) */
    NODECONFIGURATION = 32,
    /** TEMPERATURESENSOR: Represents the 6 temperature sensors in the ventilation (6 SubUnits) */
    TEMPERATURESENSOR = 33,
    /** HUMIDITYSENSOR: Represents the 6 humidity sensors (6 SubUnits) */
    HUMIDITYSENSOR = 34,
    /** PRESSURESENSOR: Represents both pressure sensors (2 SubUnits) */
    PRESSURESENSOR = 35,
    /** PERIPHERALS: Stores the ID of the ComfoCool attached, can reset peripheral errors here (1 SubUnit) */
    PERIPHERALS = 36,
    /** ANALOGINPUT: Provides data and functionality for the analog inputs, also the scaling for the voltages (4 SubUnits) */
    ANALOGINPUT = 37,
    /** COOKERHOOD: "Dummy" unit, probably represents the ComfoHood if attached (1 SubUnit) */
    COOKERHOOD = 38,
    /** POSTHEATER: Represents the optional post heater attached (temperature sens, config) (1 SubUnit) */
    POSTHEATER = 39,
    /** COMFOFOND: "Dummy" unit, represents the optional comfofond (1 SubUnit) */
    COMFOFOND = 40
}
/**
 * Known properties of each subunit.
 */
export declare const VentilationUnitProperties: {
    readonly NODE: {
        readonly SERIAL_NUMBER: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 4;
            readonly dataType: PropertyDataType.CN_STRING;
            readonly access: "ro";
        };
        readonly FIRMWARE_VERSION: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 6;
            readonly dataType: PropertyDataType.CN_UINT32;
            readonly access: "ro";
        };
        readonly MODEL_NUMBER: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 8;
            readonly dataType: PropertyDataType.CN_STRING;
            readonly access: "ro";
        };
        readonly ARTICLE_NUMBER: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 11;
            readonly dataType: PropertyDataType.CN_STRING;
            readonly access: "ro";
        };
        readonly CURRENT_COUNTRY: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 13;
            readonly dataType: PropertyDataType.CN_STRING;
            readonly access: "ro";
        };
        readonly VENTILATION_UNIT_NAME: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODE;
            readonly propertyId: 20;
            readonly dataType: PropertyDataType.CN_STRING;
            readonly access: "ro";
        };
    };
    readonly TEMPHUMCONTROL: {
        readonly RMOT_HEATING_PERIOD: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 2;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly RMOT_COOLING_PERIOD: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 3;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly PASSIVE_TEMPERATURE_CONTROL: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 4;
            readonly dataType: PropertyDataType.CN_UINT8;
            readonly access: "rw";
        };
        readonly HUMIDITY_COMFORT_CONTROL: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 6;
            readonly dataType: PropertyDataType.CN_UINT8;
            readonly access: "rw";
        };
        readonly HUMIDITY_PROTECTION: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 7;
            readonly dataType: PropertyDataType.CN_UINT8;
            readonly access: "rw";
        };
        readonly TARGET_TEMPERATURE_HEATING: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 10;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly TARGET_TEMPERATURE_NORMAL: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 11;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly TARGET_TEMPERATURE_COOLING: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.TEMPHUMCONTROL;
            readonly propertyId: 12;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
    };
    readonly VENTILATIONCONFIG: {
        readonly VENTILATION_SPEED_AWAY: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 3;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly VENTILATION_SPEED_LOW: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 4;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly VENTILATION_SPEED_MEDIUM: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 5;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly VENTILATION_SPEED_HIGH: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 6;
            readonly dataType: PropertyDataType.CN_INT16;
            readonly access: "rw";
        };
        readonly HEIGHT_ABOVE_SEA_LEVEL: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 7;
            readonly dataType: PropertyDataType.CN_UINT8;
        };
        readonly VENTILATION_CONTROL_MODE: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 9;
            readonly dataType: PropertyDataType.CN_UINT8;
        };
        readonly BATHROOM_SWITCH_ACTIVATION_DELAY: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 11;
            readonly dataType: PropertyDataType.CN_INT16;
        };
        readonly BATHROOM_SWITCH_DEACTIVATION_DELAY: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 12;
            readonly dataType: PropertyDataType.CN_UINT8;
        };
        readonly BATHROOM_SWITCH_MODE: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 13;
            readonly dataType: PropertyDataType.CN_UINT8;
        };
        readonly UNBALANCE: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.VENTILATIONCONFIG;
            readonly propertyId: 18;
            readonly dataType: PropertyDataType.CN_INT16;
        };
    };
    readonly NODECONFIGURATION: {
        readonly MAINTAINER_PASSWORD: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODECONFIGURATION;
            readonly propertyId: 3;
            readonly dataType: PropertyDataType.CN_STRING;
        };
        readonly ORIENTATION: {
            readonly node: NodeTypes.VENTILATION_UNIT;
            readonly unit: UnitTypes.NODECONFIGURATION;
            readonly propertyId: 4;
            readonly dataType: PropertyDataType.CN_UINT8;
        };
    };
};