 * @description This file contains the HeatPump class.
 * @file src/devices/heatPump.ts
 * @author Luca Liguori
 * @created 2025-06-29
 * @version 1.0.0
 * @license Apache-2.0
 *
 * Copyright 2025, 2026, 2027 Luca Liguori.
 *
 * Licensed under the Apache License, Version 2.0 (the "License");
 * you may not use this file except in compliance with the License.
 * You may obtain a copy of the License at
 *
 *     http://www.apache.org/licenses/LICENSE-2.0
 *
 * Unless required by applicable law or agreed to in writing, software
 * distributed under the License is distributed on an "AS IS" BASIS,
 * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
 * See the License for the specific language governing permissions and
 * limitations under the License.
 */
import { MatterbridgeEndpoint } from '../matterbridgeEndpoint.js';
export declare class HeatPump extends MatterbridgeEndpoint {
    /**
     * Creates an instance of the HeatPump class.
     *
     * @param {string} name - The name of the HeatPump.
     * @param {string} serial - The serial number of the HeatPump.
     * @param {number} voltage - The voltage value in millivolts.
     * @param {number} current - The current value in milliamperes.
     * @param {number} power - The power value in milliwatts.
     * @param {number} energyImported - The total production value in mW/h.
     * @param {number} [absMinPower] - Indicate the minimum electrical power in mw that the ESA can consume when switched on. Defaults to `0` if not provided.
     * @param {number} [absMaxPower] - Indicate the maximum electrical power in mw that the ESA can consume when switched on. Defaults to `0` if not provided.
     *
     * @remarks
     * - The HeatPump includes clusters for power source, electrical power measurement, electrical energy measurement, and device energy management.
     * - It also includes child devices for flow temperature, return temperature, and a thermostat.
     * - The flow and return temperature sensors are set to default values of 45.00°C and 35.00°C respectively.
     * - The heating only thermostat is set up with a default temperature setpoint of 21.00°C.
     * - The device energy management cluster is set to `esaType` as `SpaceHeating`, `esaCanGenerate` as `false`, and `esaState` as `Online`.
     * - The absolute minimum and maximum power values can be set to indicate the range of power consumption for the heat pump.
     */
    constructor(name: string, serial: string, voltage?: number | bigint | null, current?: number | bigint | null, power?: number | bigint | null, energyImported?: number | bigint | null, absMinPower?: number, absMaxPower?: number);
}