{
    "knxUltimate-config": {
        "properties": {
            "title": "KNX 网关配置",
            "host": "Gateway",
            "host_info": "默认设置为 KNX/IP 的组播地址 (224.0.23.12)",
            "port": "端口号",
            "port_info": "默认设置为 KNX/IP (3671)",
            "bind_local_int": "绑定到本地接口",
            "restart_hint": "! 更改以后重启node-red !",
            "adv_options": "高级选项",
            "ets_import": "ETS组地址列表导入",
            "node-config-input-name": "名称",
            "unsecureKNX" : "一般的 KNX 连接",
            "secureKNX" : "加密的 KNX 连接",
            "autoReconnect" : "在启动时自动链接到KNX总线",
            "autoReconnect_yes" : "是",
            "autoReconnect_no" : "否（发送 msg.connectGateway = true 到看门狗节点以此来链接KNX总线）",
            "discovering": "正在发现...",
            "interfaces_found": "个接口已发现。",
            "discovery_failed": "发现失败。",
            "address": "地址",
            "iface_auto": "自动",
            "iface_manual": "手动输入接口名称",
            "iface_name": "接口名称：",
            "iface_name_placeholder": "接口名称，例如：eth0、ens1 或 Ethernet 1 ...",
            "ip_port": "网关端口",
            "ip_protocol": "连接协议",
            "proto_auto": "自动",
            "proto_tunnel_udp": "隧道 UDP",
            "proto_multicast": "组播",
            "proto_tunnel_tcp": "隧道 TCP",
            "proto_serial_ft12": "Serial FT1.2",
            "tunnel_ia_label": "隧道接口 IA",
            "tunnel_ia_mode_auto": "自动",
            "tunnel_ia_mode_manual": "手动",
            "tunnel_ia_input_label": "接口 IA",
            "tunnel_ia_placeholder": "1.1.1",
            "secure_knx_label": "安全 KNX",
            "secure_multicast_physaddr_hint": "Secure + Multicast：你设置的物理地址将用于对 Data Secure 电报进行签名。请确保该 IA 已在 ETS 中被配置为相关组地址的发送者（Sender），否则设备会拒绝这些消息。",
            "secure_multicast_physaddr_hint_toggle": "信息",
            "serial_port_path": "Serial port path",
            "serial_refresh": "Refresh serial ports",
            "serial_discovering": "Discovering serial ports...",
            "serial_ports_found": "serial ports found.",
            "serial_ports_failed": "Unable to list serial ports.",
            "serial_baud": "Baud rate",
            "serial_data_bits": "Data bits",
            "serial_stop_bits": "Stop bits",
            "serial_parity": "Parity",
            "serial_parity_even": "Even",
            "serial_parity_odd": "Odd",
            "serial_parity_none": "None",
            "serial_rtscts": "Enable RTS/CTS hardware flow control",
            "serial_dtr": "Keep DTR asserted after connect",
            "serial_timeout": "ACK timeout (ms)",
            "serial_mode": "Serial FT1.2 模式",
            "serial_mode_kberry": "KBerry/BAOS",
            "serial_mode_standard": "标准 FT1.2"
        },
        "tabs": {
            "configuration": "配置",
            "advanced": "高级",
            "ets_import": "ETS 导入",
            "utility": "工具"
        },
        "advanced": {
            "knx_phy_addr": "KNX 物理地址",
            "show_date_status": "在状态中显示上次更新日期和时间",
            "show_device_status": "在状态中显示设备的名称 (需要 \"监听所有组地址\" )",
            "show_datapoint_status": "在状态中显示数据类型",
            "suppress_ack": "抑制 ACK 请求 in tunneling mode",
            "suppress_ack_help": "上面的选项有助于旧的 KNX/IP 接口兼容性 Warning: the node may not notice the disconnection from the gateway. In this case, use the watchdog in Ethernet+KNX twisted pair mode.",
            "ignoreTelegramsWithRepeatedFlag": "抑制重复的 (R-Flag) 来自总线的电报",
            "log_level": "日志等级",
            "nodes_list_title": "所有流中的节点列表",
            "nodes_list_help": "这是你配置的所有 KNX 节点的列表。",
            "select_silent": "没有日志输出",
            "select_trace": "跟踪",
            "select_debug": "调试",
            "select_info": "信息",
            "select_warning": "警告",
            "select_error": "错误 (默认值)",
            "tiphost": "写 EMULATE 而不是 IP 地址，模拟网关（网关不会连接到 KNX BUS）",
            "delaybetweentelegrams": "数据发送间隔时间 (毫秒)",
            "delaybetweentelegramsfurtherdelayREAD" : "并且仅在读取电报之间进一步增加延迟"      
        },
        "ets": {
            "description": "您可以导入 ETS CSV 组地址列表或 ESF 组地址列表。 请优先选择 ETS CSV 组地址列表，因为数据类型更完整.",
            "youtube" : "&nbsp<i class=\"fa fa-youtube-play\"></i>&nbsp<a target=\"_blank\" href=\"https://youtu.be/egRbR_KwP9I\"><u>在Youtube上看怎么导入CSV文件.</u></a>",
            "help_ga": "如果组地址没有数据类型",
            "import_select_stop": "停止并且中断导入",
            "import_select_skip": "跳过受影响的组地址",
            "import_select_fake": "导入并替代为一个 1.001 数据类型 (不建议)",
            "ga_list_title": "在此处粘贴从 ETS 导出的文件的内容，或文件的路径（例如：/home/pi/mycsv.csv）",
            "ga_list_help": "在此处粘贴从 ETS 导出的文件的内容，或文件的路径（例如：/home/pi/mycsv.csv）",
            "deploywithETS": "将执行一些控制操作。 任何问题都会在右侧的调试窗口中报告.",
            "keyring":"在这里粘贴从 ETS 导出的 Keyring XML 文件的内容",
            "youtubeKeyring": "在 Youtube 上了解如何导出 Keyring XML 文件",
            "keyring_file": "Keyring 文件",
            "password": "密码",
            "secure_credentials_mode": "安全凭据来源",
            "secure_credentials_mode_keyring": "ETS 密钥环文件",
            "secure_credentials_mode_manual": "手动凭据",
            "secure_credentials_mode_combined": "密钥环 + 手动隧道密码",
            "tunnel_interface_individual_address": "隧道接口个人地址",
            "tunnel_interface_individual_address_placeholder": "1.1.1",
            "tunnel_user_id": "隧道用户 ID",
            "tunnel_user_password": "隧道用户密码",
            "ga_list_label": "ETS 组地址列表"
        },
        "utility": {
            "gather_debug": "收集调试信息和日志以便排查",
            "get_all_used_ga": "获取 KNX 路由过滤器使用的所有 GA",
            "read_button": "读取",
            "copy_ga_router": "将这些组地址复制到 KNX/IP 路由器的路由表中。"
        }
    }
}
