# node-red-contrib-myhome-bticino-v2

Control Bticino / Legrand MyHome&#8482; components from Node-RED : node-red-contrib-myhome-bticino-v2 is a Node-RED nodes pack to interact with Bticino / Legrand MyHome&#8482; devices making use of [OpenWebNet](https://en.wikipedia.org/wiki/OpenWebNet) protocol through a supported gateway (see gateway info underneath).

## 1. Available nodes
- **MH Light**
	- ON / OFF / TOGGLE
	- Dimming : UP / DOWN / percentage based
- **MH Shutter**
	- OPEN / CLOSE / STOP
- **MH Scenario**
	- CEN and CEN+ scenario buttons management : Short and Long press (start / extended / release)
- **MH Temperature Central Unit**
	- MANUAL:xx.x°C / PROGRAM:x / SCENARIO:xx / OFF / ANTIFREEZE / THERMAL_PROTECT
- **MH Temperature Zone**
	- (MANUAL:)xx.x°C / AUTO / OFF / ANTIFREEZE / THERMAL_PROTECT
- **MH Energy**
	- Read energy meters power consumption measurements
- **MH Monitoring**
	- Listen for any message on the bus and sends it as payload
- **MH Inject**
	- Sends any message provided in payload to bus. e.g.
		- **`*1*1*16##`** to turn on light **16**
		- **`*#1*16##`** to ask for status about light **16**, receiving as a response **`*1*1*16##`** when is ON or **`*1*0*16##`** when is OFF

## 2. Version history
### v2.4.0 (latest available) - 01/2025
- **MH Monitoring**
  - ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.ownFamilyName` and `.gateway` (object)
  - ***Improvement*** : node has a second output which provides a structured payload object with analyzed information based on BUS received content, as it would be output by a specialized light, shutter,... node. It makes the monitoring node usable as a sort of 'universal node' : all events of one or multiple family types can be processed from a single monitoring node instead of having to add a node for each light, shutter,... point.
  This currently supports (see Monitoring node documentation for full detailed payload content):
    - **Lights** : any light point / group call
    - **Shutters** : any shutter point / group call
    - **Temperature** : only outputs current temperature update for any zone
    - **Scenario** : outputs any button press for CEN/CEN+
    - **Energy** : only outputs current consumption (instant) of any meter
- **MH Light**
  - ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic`, `.buslevel`, `.lightid`, `.isgroup` and `.gateway`*[object]*
- **MH Shutter**
	- ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic`, `.buslevel`, `.shutterid`, `.isgroup` and `.gateway`*[object]*
- **MH Scenario**
	- ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic`, `.buslevel`, `.scenarioid`, `.scenariotype` and `.gateway`*[object]*
- **MH Temperature Central Unit**
	- ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic` and `.gateway` *[object]*
- **MH Temperature Zone**
	- ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic`, `.zoneid` and `.gateway` *[object]*
- **MH Energy** :
	- ***Improvement*** : new object included in returned msg (`.mh_nodeConfigInfo`) which contains configuration node info : `.name`, `.topic`, `.meterid`, `.metertype`, `.meterscope` and `.gateway` *[object]*

The **complete version history** is available in `CHANGELOG.md` file included in npm package or using this link to [GitHub repository](https://github.com/FredBlo/node-red-contrib-myhome-bticino-v2/blob/main/CHANGELOG.md)

## 3. Installation
  Note : Using the previous node version [node-red-contrib-myhome-bticino](https://flows.nodered.org/node/node-red-contrib-myhome-bticino) ? See more upgrade info/path in revision history file.
- Easy approach when **Node-RED is installed**
	If you have Node-RED already installed the recommended install method is to use the editor. To do this, select `Manage Pallette` from the Node-RED menu (top right), and then select `install` tab in the pallette. Search for and install this node (`node-red-contrib-myhome-bticino-v2`).

- Using **NPM**
	If you have not yet installed Node-RED then run following command or go to [Node-RED Installation Guide](https://nodered.org/docs/getting-started/installation).

        npm install -g --unsafe-perm node-red

    Next, to install node-red-contrib-myhome-biticino node run the following command in your Node-RED user directory - typically `~/.node-red`

        npm install node-red-contrib-myhome-bticino-v2

## 4. Usage
### 4.1 First touch
In order to easy starting to test the nodes, best way is to import an example provided with installed content (using node-red menu **'Import'** and selecting one listed under 'node-red-contrib-myhome-bticino-v2'in the **'examples'** tab).
Examples are available for :
- MH Energy
- MH Light (simple point)
- MH Light (group of lights)
- MH Shutter
- MH Scenario (CEN / CEN+)
- MH Temperature Central Unit
- MH Temperature Zone
- MH Inject
- MH Monitoring (discover lights)

<img attr="MH Nodes Examples" src="https://raw.githubusercontent.com/FredBlo/node-red-contrib-myhome-bticino-v2/main/.resources/HowTo_Import_Example.gif" width="100%">

You can also directly copy this basic flow in Node-RED selecting **Import** in the node-red menu, pasting the provided JSON (do not forget to change the **IP address in the Gateway** configuration and of course the light number in switch node) :

```
[{"id":"aaec927e.81712","type":"myhome-light","z":"6fa4a1d5.ce7708","lightid":"15","isgroup":false,"topic":"light","gateway":"a4e23617.d0c288","name":"My test light (A=1 / PL=5)","skipevents":false,"isstatusrequest":false,"output2_name":"","output2_type":"boolean","x":450,"y":180,"wires":[["d0e9bd53.eb9a2"],[]]},{"id":"d0e9bd53.eb9a2","type":"debug","z":"6fa4a1d5.ce7708","name":"","active":true,"tosidebar":true,"console":false,"tostatus":false,"complete":"false","statusVal":"","statusType":"auto","x":650,"y":140,"wires":[]},{"id":"64655a39.b6822c","type":"inject","z":"6fa4a1d5.ce7708","name":"ON","props":[{"p":"payload"},{"p":"topic","vt":"str"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"cmd/light","payload":"true","payloadType":"bool","x":190,"y":160,"wires":[["aaec927e.81712"]]},{"id":"ffdb52e3.aa532","type":"inject","z":"6fa4a1d5.ce7708","name":"OFF","props":[{"p":"payload"},{"p":"topic","vt":"str"}],"repeat":"","crontab":"","once":false,"onceDelay":0.1,"topic":"cmd/light","payload":"false","payloadType":"bool","x":190,"y":200,"wires":[["aaec927e.81712"]]},{"id":"9fa0e5b6.9a17f","type":"myhome-eventsession","z":"6fa4a1d5.ce7708","gateway":"a4e23617.d0c288","name":"Discover number","own_lights":true,"own_shutters":true,"own_temperature":false,"own_energy":false,"own_others":false,"x":480,"y":260,"wires":[["193b7155.0724e7"]]},{"id":"193b7155.0724e7","type":"debug","z":"6fa4a1d5.ce7708","name":"","active":true,"tosidebar":true,"console":false,"tostatus":false,"complete":"false","statusVal":"","statusType":"auto","x":690,"y":260,"wires":[]},{"id":"a4e23617.d0c288","type":"myhome-gateway","name":"F-455","host":"192.168.0.210","port":"20000","pass":"12345","timeout":"600","log_in_lights":false,"log_in_shutters":false,"log_in_temperature":false,"log_in_energy":false,"log_in_others":false,"log_out_cmd":false}]
```

### 4.2 SCS BUS addresses
When adding nodes, you have to provide the BUS address (known as 'A/PL' in MyHome). The references used in nodes are to be set as a single value : `A=1 PL=5` becomes `15`, also be aware that, when A>9 or PL>9, the format becomes 4 digits, e.g. `A=11 PL=5` becomes `1105`, `A=1 PL=15` becomes `0115`.

### 4.3 Tips : How to discover device A/PL
Import the provided example node 'MH Monitoring (discover lights)' and follow info and comments :-)

## 5. Bticino Gateway & OpenWebNet
BTicino is using a proprietary protocol (SCS) to communicate from/to the devices in MyHome network system. There are a many gateways able to convert SCS protocol to OpenWebNet protocol that is well documented (follow this [link](https://developer.legrand.com/documentation/open-web-net-for-myhome/) for more details) and quite easy to use.
Based on previous authors comments and my own experience when testing/extending these nodes, these are the gateways it supports :

| Gateway             | Authentication (tested)           | Lights    | Shutters  | Scenario   | Temperature  | Energy   |
| ------------------- | --------------------------------- | --------- | --------- | ---------- | ------------ | -------- |
| ***MH201*** \*      | IP, OPEN pwd                      | OK [1]    | OK        | ?          | ?            | ?        |
| ***MH202***         | OPEN pwd                          | OK        | OK        | OK         | OK [3][4]    | OK       |
| ***F455***          | IP, OPEN pwd, HMAC (SHA-1) pwd [2]| OK        | OK        | OK         | OK [4]       | OK [6]   |
| ***F459***          | IP, OPEN pwd, HMAC (SHA-2) pwd    | OK        | OK        | OK         | OK           | OK       |
| ***myHOMEServer1*** | HMAC (SHA-2) pwd                  | OK        | OK        | OK         | OK [5]       | OK       |

\*based on *Fabio Bui* feedback
\
[1] MH201 gateway does not 'respond' to light status request (on update or in read-only mode), but the response itself is sent on the BUS and can be read/used through another flow if necessary. See more info on [GitHub issue 11](https://github.com/FredBlo/node-red-contrib-myhome-bticino-v2/issues/11)
\
[2] F455 gateway closes the monitoring connection after 1 hour of inactivity. The connector will auto-reconnect but it is best to use 'keep alive' enabled every 10-15 minutes to avoid connection drops.
\
[3] MH202 gateway returns the temperature set-point without taking the local offset into account
\
[4] MH202 & F455 gateways will only send status of first zone's actuator (asking for all fails)
\
[5] myHOMEServer1 does not allow switching a zone to manual heating (specifying a manual temperature set point)
\
[6] F455 returns -very- unstable/awkward results for hourly and daily calls. Nodes caching must be enabled to correct most of them when nodes are running for a while...


## 6. Contact me
If you have questions, remarks, issues,... please add your input using GitHub for this project (either [issues](https://github.com/FredBlo/node-red-contrib-myhome-bticino-v2/issues) or [discussions](https://github.com/FredBlo/node-red-contrib-myhome-bticino-v2/discussions))