# Smart-Boiler
        
 this node belongs to a suite of nodes to control heating made by multiple intelligent Valve and a Central Boiler.
 The scheduling is done by Smart-Scheduler where multiple schedule and set-point can be defined,
 The valve management is done by Smart-Valve where multiple valve can be grouped in one room or group of room. 
 And finally Smart-Boiler aims to control the boiler and to determine the right temperature and set point seeting according to the multiple valves.
 
 <b>Smart-Boiler</b>
 Received input from Smart-Valves and expect message as :
 msg.payload with:
 - sp for setpoint, int value
 - temp for current valve temperature, int value,
 - name for valve description, string value,
 - id for unique valve identification, int value
 ex input message:
 msg.payload={ sp:23,temp:20,name:"Valve kitchen", id:1}
 Each input received will either create a new entry in the valves stack or update the current entry in the stack.
 Smart-Boiler will determined the active valve to be sent to the Boiler, the active valve is determine by valve set point (target temperature) > valve current temperature 
 and by the highest gap between set point and current temperature.
 Exemple : 
 - Valve A : set point 19°C, current temperature 21 °C => inactive
 - Valve B : set point 23°C, current temperature 20 °C, gap is 3 °C => active but not sent to boiler,
 - Valve C : set point is 24°C and current temperature is 19°C, gap is 5°C => active and sent to the boiler.
 
 Additionnal functionnal rules:
 
 - If no active valve is found then highest sp of inactive valve is set as a reference to the boiler. 
 - If no input after max duration (defined in setting), security message is sent to the boiler to avoid endless heating,
 
 Output: 
 - Can be directly to MQTT (preferred);
 - regular output: 
 msg.payload={ sp:23,temp:20,name:"Valve kitchen", id:1, lastTsUpdate: ISOTIME};
 Configuration settings: 
 MQTT: configuration node to define mqtt server connexion
 MQTT updates: when checked, update messages are directly sent to the defined topics
 Output updates: when checked, update messages are sent to the regular output,
 Set point topic: MQTT set Boiler set point topic
 Temperature topic: MQTT set Boiler current temperature topic
 Leading Device topic: MQTT Boiler text topic to indicate which valves is driving the heating
 Update cycle duration: valve stack evaluation duration cycle
 Max Duration since last input: maximum duration before sending security message to the boiler with default values
 Default temp: security message is sent with default temp
 Default set point: security message is sent with default set point