# Smart-valve 
    
The purpose of this project was to replace at my house the existing NETATMO system (very good but not integrated in Home assistant and with no repeater).

I have a boiler with Opentherm Card and a dedicated dev with ESP32 https://github.com/vibr77/Opentherm_HA_MQTT


Changelog 20240102:
- Add a mecanism for manual update on the TRV (wip)

Changelog 20231031: 
- Fixe BRT-100-TRV firmware issue (TRV wrong position stay at 25% open position) with a work around on current temperature

Smart-Valce is part of a suite of nodes to manage multi room heating system based on TRV and boiler
- Smart-Scheduler: multi-zonning SmartScheduler,
- Smart-Valve: Valve grouping, auto-calibration, manual override,
- Smart-Boiler: Boiler OpenTherm, multi valve management.

## Smart-valve

 This node enables to manage multiple valve (climate) in a same room like one. 
 It support the following features :
 - External temperature sensor,
 - Multiple valves updates,
 - TRV temperture Recalibration based on the external temperature sensor,
 - Manual update directly on the valve to trigger override message to the scheduler and update the other valve

### Key Features:
- TRV auto calibration with an external source
- Detection of manual update direcly on TRV
- Fixe BRT-100-TRV issue on valve postion that stay open
- Multi valves in the same room management
- Multi mode execution Off / auto / Manual
- Multi trigger execution: every cycle, at startup, on change.



### Inputs
    
 - payload (string):[1|on|trigger]
 - sp (integer): [0-35]    
 
 ## Outputs
 
 1. Update home assistant via call service
 
 2. Update of SP to the boiler (smart-Boiler) or override message to the smart-scheduler
    
### Settings

- Name: [string], name of the node and also the name of the group sent to the smart-boiler node
- Topic: [string], not used,
- Group Id: [integer], used by the smart-boiler node to identify this group of valves, need to be unique

- Temperature: [string], is the name of the external temperature sensor entity in home assistant ex: sensor.temp9
- Update mode: [state changed|state changed+startup|every cycle], define how frequently updates are sent to the smart-boiler node
- Update cycle: [integer], duration in minute between two cycle. default is 5
- Allow manual updates: [true|false], enable direct set point (target temperature) change on the valve or home assistant. If true when a valve set point ischanged all the other valves are updated and a override message is sent to the smart-scheduler node.
- Recalibration: [No|Yes|Yes+threshold], enable to adjust the valve (TRV) current temperature based on the external temperature sensor,
- Delta threshold: [integer] [0-9], threshold delta between external temperature sensor and the TRV current temperature to trigger recalibration,
- Debug: [true|false], send debug info to the node-red console
- Climate: each valve entry has 2 field:
     - climate: [string], home assitant climate entity of the valve ex: climate.kitchen
     - calibration: [string], home assistant calibration entity of the valve ex: number.kitchen_calibration
    
### Execution rules 
- Step 0: update current group setpoint with the sp of the valve,
- Cycle :
    Step 1: identify if manual updates on valve, then update all valves,
    Step 2: check and execute recalibration
    Step 3: based on the execution mode, output to the smart-boiler node
- On input: 
    Update the requested set-point on each valves




<a href="https://www.buymeacoffee.com/vincentbe" target="_blank"><img src="https://cdn.buymeacoffee.com/buttons/v2/default-yellow.png" alt="Buy Me A Coffee" style="height: 60px !important;width: 217px !important;" ></a>