/* eslint-disable */
/**
 * This file was automatically generated by json-schema-to-typescript.
 * DO NOT MODIFY IT BY HAND. Instead, modify the source JSONSchema file,
 * and run json-schema-to-typescript to regenerate this file.
 */

/**
 * Sampled_ Value. Context. Reading_ Context_ Code
 * urn:x-oca:ocpp:uid:1:569261
 * Type of detail value: start, end or sample. Default = "Sample.Periodic"
 *
 */
export type ReadingContextEnumType =
  | "Interruption.Begin"
  | "Interruption.End"
  | "Other"
  | "Sample.Clock"
  | "Sample.Periodic"
  | "Transaction.Begin"
  | "Transaction.End"
  | "Trigger";
/**
 * Sampled_ Value. Measurand. Measurand_ Code
 * urn:x-oca:ocpp:uid:1:569263
 * Type of measurement. Default = "Energy.Active.Import.Register"
 *
 */
export type MeasurandEnumType =
  | "Current.Export"
  | "Current.Import"
  | "Current.Offered"
  | "Energy.Active.Export.Register"
  | "Energy.Active.Import.Register"
  | "Energy.Reactive.Export.Register"
  | "Energy.Reactive.Import.Register"
  | "Energy.Active.Export.Interval"
  | "Energy.Active.Import.Interval"
  | "Energy.Active.Net"
  | "Energy.Reactive.Export.Interval"
  | "Energy.Reactive.Import.Interval"
  | "Energy.Reactive.Net"
  | "Energy.Apparent.Net"
  | "Energy.Apparent.Import"
  | "Energy.Apparent.Export"
  | "Frequency"
  | "Power.Active.Export"
  | "Power.Active.Import"
  | "Power.Factor"
  | "Power.Offered"
  | "Power.Reactive.Export"
  | "Power.Reactive.Import"
  | "SoC"
  | "Voltage";
/**
 * Sampled_ Value. Phase. Phase_ Code
 * urn:x-oca:ocpp:uid:1:569264
 * Indicates how the measured value is to be interpreted. For instance between L1 and neutral (L1-N) Please note that not all values of phase are applicable to all Measurands. When phase is absent, the measured value is interpreted as an overall value.
 *
 */
export type PhaseEnumType = "L1" | "L2" | "L3" | "N" | "L1-N" | "L2-N" | "L3-N" | "L1-L2" | "L2-L3" | "L3-L1";
/**
 * Sampled_ Value. Location. Location_ Code
 * urn:x-oca:ocpp:uid:1:569265
 * Indicates where the measured value has been sampled. Default =  "Outlet"
 *
 *
 */
export type LocationEnumType = "Body" | "Cable" | "EV" | "Inlet" | "Outlet";

/**
 * Request_ Body
 * urn:x-enexis:ecdm:uid:2:234744
 *
 */
export interface MeterValuesRequest {
  customData?: CustomDataType;
  /**
   * Request_ Body. EVSEID. Numeric_ Identifier
   * urn:x-enexis:ecdm:uid:1:571101
   * This contains a number (>0) designating an EVSE of the Charging Station. ‘0’ (zero) is used to designate the main power meter.
   *
   */
  evseId: number;
  /**
   * @minItems 1
   */
  meterValue: [MeterValueType, ...MeterValueType[]];
}
/**
 * This class does not get 'AdditionalProperties = false' in the schema generation, so it can be extended with arbitrary JSON properties to allow adding custom data.
 */
export interface CustomDataType {
  vendorId: string;
  [k: string]: unknown;
}
/**
 * Meter_ Value
 * urn:x-oca:ocpp:uid:2:233265
 * Collection of one or more sampled values in MeterValuesRequest and TransactionEvent. All sampled values in a MeterValue are sampled at the same point in time.
 *
 */
export interface MeterValueType {
  customData?: CustomDataType;
  /**
   * @minItems 1
   */
  sampledValue: [SampledValueType, ...SampledValueType[]];
  /**
   * Meter_ Value. Timestamp. Date_ Time
   * urn:x-oca:ocpp:uid:1:569259
   * Timestamp for measured value(s).
   *
   */
  timestamp: string;
}
/**
 * Sampled_ Value
 * urn:x-oca:ocpp:uid:2:233266
 * Single sampled value in MeterValues. Each value can be accompanied by optional fields.
 *
 * To save on mobile data usage, default values of all of the optional fields are such that. The value without any additional fields will be interpreted, as a register reading of active import energy in Wh (Watt-hour) units.
 *
 */
export interface SampledValueType {
  customData?: CustomDataType;
  /**
   * Sampled_ Value. Value. Measure
   * urn:x-oca:ocpp:uid:1:569260
   * Indicates the measured value.
   *
   *
   */
  value: number;
  context?: ReadingContextEnumType;
  measurand?: MeasurandEnumType;
  phase?: PhaseEnumType;
  location?: LocationEnumType;
  signedMeterValue?: SignedMeterValueType;
  unitOfMeasure?: UnitOfMeasureType;
}
/**
 * Represent a signed version of the meter value.
 *
 */
export interface SignedMeterValueType {
  customData?: CustomDataType;
  /**
   * Base64 encoded, contains the signed data which might contain more then just the meter value. It can contain information like timestamps, reference to a customer etc.
   *
   */
  signedMeterData: string;
  /**
   * Method used to create the digital signature.
   *
   */
  signingMethod: string;
  /**
   * Method used to encode the meter values before applying the digital signature algorithm.
   *
   */
  encodingMethod: string;
  /**
   * Base64 encoded, sending depends on configuration variable _PublicKeyWithSignedMeterValue_.
   *
   */
  publicKey: string;
}
/**
 * Represents a UnitOfMeasure with a multiplier
 *
 */
export interface UnitOfMeasureType {
  customData?: CustomDataType;
  /**
   * Unit of the value. Default = "Wh" if the (default) measurand is an "Energy" type.
   * This field SHALL use a value from the list Standardized Units of Measurements in Part 2 Appendices.
   * If an applicable unit is available in that list, otherwise a "custom" unit might be used.
   *
   */
  unit?: string;
  /**
   * Multiplier, this value represents the exponent to base 10. I.e. multiplier 3 means 10 raised to the 3rd power. Default is 0.
   *
   */
  multiplier?: number;
}